Soltree Logo
EN

Custom configurations · Project supply

PV Combiner Boxes.
Built Around Your Project.

From your wiring diagram to an agreed box configuration. Work with Soltree on protection components, enclosure layout and OEM details for your solar project.

Built to Your Diagram

Circuit layouts and protection configured around your project.

Your Brand, Your Box

Logo, nameplate and packaging options for your brand.

Ready for Project Supply

Supply quantities and delivery plans agreed for your project.

Configure the details

Your Project. Your Configuration.

Start with an existing box or your own specification. Configure these six areas around your installation, procurement and brand requirements.

Circuit configuration

String inputs, outputs and inverter connections matched to your diagram, with independent MPPT circuits kept separate where required.

Protection & switching

DC breakers or isolators, PV fuses and surge protection, with ratings and coordination reviewed for your circuit.

Enclosure & layout

Steel or plastic housing, cable entries and internal layout planned around your installation and maintenance access.

Wiring & connections

Cable sizes, connectors, polarity markings and internal routing specified for the approved configuration.

OEM identification

Your logo, nameplate, circuit labels and packaging for a consistent brand presentation.

Project documentation

Drawings, component lists and inspection records, with market-specific document requirements reviewed for your project.

Have a drawing or specification?

Send it with your quantity and destination to start a configuration review.

Send Your Drawing

Inside the combiner box

PV Combiner Box Internal Wiring

Explore eight input and voltage configurations. Some cards currently share an illustrative reference image; actual components and wiring depend on the approved configuration drawing.

Shared illustrative internal wiring reference showing PV fuses, surge protection, a circuit breaker and marked connections

2 in / 1 out · 500V DC

Shared illustrative internal wiring reference showing PV fuses, surge protection, a circuit breaker and marked connections

2 in / 1 out · 1000V DC

Shared illustrative internal wiring reference showing PV fuses, surge protection, a circuit breaker and marked connections

3 in / 1 out · 1000V DC

Shared illustrative internal wiring reference showing PV fuses, surge protection, a circuit breaker and marked connections

4 in / 1 out · 1000V DC

Shared illustrative internal wiring reference showing PV fuses, surge protection, a circuit breaker and marked connections

8 in / 1 out · 1000V DC

Shared illustrative internal wiring reference showing PV fuses, surge protection, a circuit breaker and marked connections

9 in / 1 out · 1000V DC

Shared illustrative internal wiring reference showing PV fuses, surge protection, a circuit breaker and marked connections

10 in / 1 out · 1000V DC

Shared illustrative internal wiring reference showing PV fuses, surge protection, a circuit breaker and marked connections

12 in / 1 out · 1000V DC

Project configuration examples

From Project Brief to Box Configuration.

Two customer projects, one plastic and one steel, showing how the box configuration follows the string count, current and installation site.

HT 8-way plastic PV combiner box wall-mounted beside a rooftop solar array
Plastic enclosure Customer project

2-in / 1-out Plastic Combiner Box

Solar installer / South Africa / Rooftop PV

Two rooftop strings combined into one inverter input, supplied as a pre-wired box the installer reorders under one part number.

Inputs / outputs
2 in / 1 out
Max system voltage
600V DC
DC breaker
63A
PV fuses
4 × 15A
Surge protection
500V DC · 40kA
Enclosure
Flame-retardant plastic · IP65

Why this enclosure: A compact, lightweight housing for wall mounting on residential roofs, with the same layout on every repeat order.

Steel PV combiner box mounted on a solar carport column with cable tray
Steel enclosure Customer project

6-input Steel Combiner Box

Engineering procurement / Multi-string PV

Six PV strings combined into one 125A output for a larger array, with internal space for organized wiring and maintenance.

Inputs / outputs
6 in / 1 out
DC breaker
125A
PV fuses
6 × 15A
Surge protection
500V DC · 40kA
Enclosure
Steel · IP65
Security
Safety lock & key

Why this enclosure: A steel, lockable enclosure for sites where the box is exposed to impact or unauthorized access.

Project gallery

More Projects Around the World

Ground-mounted solar panels and combiner equipment at an Austrian hillside farm

Austria · 1.1 MW

Hillside Farm Solar Project

Inverters and DC combiner boxes in a Malaysian oilfield PV and storage system

Malaysia · 10 kW

Oilfield PV & Energy Storage

Rows of solar panels at a ground-mounted PV project in Xinjiang, China

Xinjiang, China · 10 MW

Ground-Mount Solar Project

Rooftop photovoltaic installation in Zhejiang, China

Zhejiang, China · 46 kW

Rooftop Solar Project

Open PV combiner box mounted beneath a solar array in the United States

United States · 32 kW

PV Combiner Box Installation

Applications & partnerships

Built for Solar Projects & OEM Partners.

Work with Soltree as an EPC contractor, solar installer or OEM partner to align the box configuration with your installation and procurement requirements.

Commercial & industrial rooftops

Plan configurations around roof zones, inverter connections and maintenance access, with clear circuit identification across the installation.

Ground-mount solar projects

Discuss enclosure requirements, cable entries and supply batches around the site environment and project delivery schedule.

OEM & distribution partners

Agree a repeat-order configuration with consistent components, brand identification and packaging requirements for your market.

Discuss Your Project
Soltree factory exterior with the SOLTREE sign, rooftop solar panels and loading area
Soltree factory · DC electrical products & PV combiner box supply

Meet your manufacturing partner

DC Protection Products.
PV Combiner Box Manufacturing.

With over 15 years of manufacturing expertise, Soltree provides DC protection products and PV combiner boxes at competitive prices. We support installers, project buyers and OEM partners with plastic or steel enclosures, custom configurations and coordinated project supply.

Our range includes DC circuit breakers, surge protectors, PV fuses and complete combiner box assemblies. From component selection and enclosure layout to branding and packaging, we help turn your project requirements into an agreed production specification for consistent repeat orders.

98.9%

Customer satisfaction

Dedicated support and responsive service.

  • DC protection components
  • PV combiner box assembly
  • OEM & custom configurations
  • Wholesale & project supply

Soltree factory capabilities at a glance

Manufacturing experience
15+ Years
International certifications
100+
PV combiner box industry
Leading Manufacturer
Global partners
3,000+
Core R&D team
30+ Specialists
Employees
100+
2025 production value
CNY 80M+
Factory floor area
10,000+ m²

From DC Components to a Complete Combiner Box

Source DC protection components or a complete PV combiner box, configured for your project.

Overcurrent protection

DC Circuit Breakers

DC breakers selected for your system voltage, current, breaking capacity and pole arrangement.

Explore DC MCBs →

Surge protection

DC Surge Protectors

PV surge protection matched to your system voltage, earthing arrangement and box design.

Explore DC SPDs →

String protection

PV Fuses & Wiring

PV fuses, holders, terminals and wiring specified for your string current and circuit layout.

Discuss Components →

Configured assemblies

PV Combiner Boxes

Plastic or steel boxes with configured inputs, outputs and protection, plus OEM branding options.

View Configurations →

Inside Soltree

A Closer Look at Our Factory

Production workshops, quality inspection, warehousing and our technical team — from manufacturing to packing and shipping.

Workers assembling and wiring PV combiner boxes at workshop benches
Assembly Workshop
Open steel PV combiner boxes with installed protection components and wiring
Combiner Box Assembly
Staff fitting protective foam corners to a steel enclosure before packing
Protective Packaging
Workshop storage shelves with electrical components, cables and packed boxes
Component Storage
Worker wiring a combiner box beside cable processing equipment
Wiring & Production

From enquiry to supply

From Your Drawing to Project Delivery.

Agree the configuration, approval requirements and supply scope before production begins.

  1. Step 01

    Project brief

    Share your drawing, inverter details, quantity and destination. Flag any requirements still to be decided.

  2. Step 02

    Configuration review

    Review the circuit, protection components, enclosure layout and required documents together.

  3. Step 03

    Specification approval

    Approve drawings and the component list before production. Confirm whether a sample or first article is needed.

  4. Step 04

    Production & delivery

    Coordinate inspection, labeling, packing and shipment batches against the agreed delivery plan.

Selection · Customization · Project orders

PV Combiner Box FAQs

Answers to common questions about inverter connections, outdoor enclosures, OEM options and project supply. Have a drawing or specification? Send it with your enquiry for review.

System selection & protection

What does a PV combiner box do?

A PV combiner box brings string circuits into an organized enclosure for connection and protection. Depending on the design, it combines strings into a shared output or keeps circuits separate for independent inverter inputs. It does not convert DC power to AC.

Does every solar installation need an external combiner box?

The inverter connection plan determines whether an external box is needed. Review its available string inputs and built-in protection against the array layout and project requirements. Send the inverter data sheet and string plan rather than selecting a box by system power alone.

How do I choose a PV combiner box for my inverter?

Start with the inverter model and wiring diagram. Confirm string inputs, outputs, design voltage and current, then review protection and enclosure requirements. Our configuration examples are references; the final selection follows your approved project specification.

Which protection components are included?

The component list is configuration-specific. Our project examples include PV fuses, a DC breaker and surge protection. Switching devices, cable sizes and connections are reviewed together before approval.

Can one box serve multiple inverter MPPT inputs?

Yes, with a layout that preserves the independent circuits required by the inverter. Multiple outputs do not necessarily share one combined bus. Send the inverter model and wiring diagram so we can review each circuit and combining point.

What does 2-in / 1-out or 2-in / 2-out mean?

These labels describe input and output counts. A 2-in / 1-out design typically combines two strings, while a 2-in / 2-out design can preserve two separate circuits. Always check the wiring diagram: the label alone does not confirm internal connections or MPPT compatibility.

How should I specify system voltage and current?

Provide module Voc and Isc, modules per string, parallel string count and the site minimum temperature. The design review must account for cold-weather string voltage, inverter limits, cable ratings and protection coordination. A power rating in kW alone is insufficient.

Can I use a PV combiner box for AC circuits or batteries?

Only use a box approved for the intended circuit. Our featured examples are PV DC configurations. AC aggregation and battery protection require separate reviews of device ratings, fault current, switching and wiring; a matching voltage label alone does not establish suitability.

Enclosures, installation & maintenance

Are your PV combiner boxes suitable for outdoor installation?

Our featured plastic and steel boxes specify IP65. Confirm the selected model, seals, cable entries and site conditions before installation; an IP65 rating does not permit submersion.

Should I choose a plastic or steel enclosure?

Our plastic project example prioritizes light weight and compact wall mounting. The steel example adds a lockable housing for exposed sites. Choose around installation space, access and environmental requirements.

Can the box be installed in coastal, hot or cold environments?

Share the site temperature range, sun exposure, humidity and salt or chemical exposure. Enclosure material, seals, component operating limits and thermal performance must be reviewed for that location. The featured IP65 rating alone does not confirm UV, corrosion or temperature suitability.

Are the boxes supplied pre-wired?

Our two featured customer configurations are pre-wired assemblies. Confirm the supplied components, external terminations, cable entries and installation documents in your order specification. Pre-wiring still requires on-site mounting, connection and commissioning.

Who should install and commission the combiner box?

Use a qualified PV installer or electrician following the supplied instructions and local requirements. Commissioning includes checks of polarity, connections, protective earthing and the approved circuit arrangement. PV conductors can remain live in daylight after the inverter is switched off.

What routine maintenance is required?

Follow the selected assembly instructions for inspection intervals. Check for water ingress, damaged seals, loose or overheated connections and protection-device status. Internal work requires qualified personnel, isolation of all relevant sources and verification of a safe working condition; never open fuse holders under load.

How do I select replacement fuses or SPD modules?

Use the approved component list and device instructions. Match the fuse type and electrical ratings, or the SPD module and compatible base. Send the box identification and component label for review before substituting a part.

Customization, OEM & documentation

Can you customize a PV combiner box to our drawing?

Yes. Soltree reviews circuit inputs and outputs, protection components, enclosure layout, cable entries and wiring against your drawing. OEM options include your logo, nameplate, circuit labels and packaging. The quotation and approved specification define the final scope.

Can cable entries and connectors match our installation?

Yes, cable entry positions, cable sizes, connectors and internal routing can be specified during layout review. Include your cable and mating-connector details so mechanical fit, electrical compatibility, sealing and installation access can be checked together.

Can I request monitoring or additional protection functions?

Include a separate schedule for functions such as string monitoring, remote alarms or reverse-current protection. Specify the measurements, interface and operating requirements. These are project requirements to review, rather than standard features of every configuration shown here.

Which certificates and inspection documents can you provide?

Send the standards, certificates and inspection records required by your project or market. We will confirm which documents apply to the proposed assembly and components. Component certificates do not automatically certify the complete box.

What is confirmed before production starts?

The agreed scope should identify the wiring diagram, component list, enclosure layout, electrical ratings, labels, packaging and required documents. Confirm any sample approval criteria and inspection requirements before releasing the order for production.

Can you support consistent configurations for repeat orders?

Yes. Agree a repeat-order configuration with defined components, layout, identification and packaging. Reference the previous order and approved drawing revision, and confirm any proposed changes before production so different batches remain aligned with your project requirements.

Quotations, delivery & after-sales

What are the MOQ and lead time for custom orders?

MOQ and production lead time are quoted for the agreed configuration, quantity and sample requirements. Include your destination and target arrival date so production and transit can be planned separately.

Do you offer samples before a project order?

Request a sample or first article with your enquiry. Its specification, cost and schedule will be confirmed before proceeding; agree any approval criteria before production.

What should I send for an EPC quotation or tender enquiry?

Email your single-line diagram, inverter model, electrical requirements and bill of quantities to shawn@cnsoltree.com. Include enclosure requirements, mandatory documents, destination and delivery milestones. You can also start with the enquiry form below and send drawings by email.

How are packing and shipping arranged?

Packing, shipment batches, destination and delivery responsibilities are agreed with the order. Include handling or labeling requirements in your enquiry.

What warranty and after-sales terms apply?

Confirm the warranty period, coverage and support arrangements in your quotation or contract. For a product issue, send the order reference, configuration and photos to help us review it.

Do you charge for design or custom tooling?

Ask for design, sample, tooling and production costs to be identified in the quotation. Charges depend on the requested scope; confirm ownership and reuse terms if your project requires dedicated tooling or a proprietary enclosure.

Custom box · OEM · Project quotation

Tell Us What Your Project Needs.

Have a complete specification or just an initial layout? Send what you have and tell us which details need support.

  • 01 — Inverter model, string inputs and output arrangement
  • 02 — Design voltage, current and protection requirements
  • 03 — Enclosure, installation environment and branding
  • 04 — Quantity, destination, documents and target delivery

For drawings and attachments, email us directly with your project name.

Request a Project Review

Share your requirements for a configuration and quotation discussion.

Chat with Soltree

Product selection & quotations

Tell us your product requirements. Our team will help you find the right solution.