Circuit configuration
String inputs, outputs and inverter connections matched to your diagram, with independent MPPT circuits kept separate where required.
Custom configurations · Project supply
From your wiring diagram to an agreed box configuration. Work with Soltree on protection components, enclosure layout and OEM details for your solar project.
Circuit layouts and protection configured around your project.
Logo, nameplate and packaging options for your brand.
Supply quantities and delivery plans agreed for your project.
Configure the details
Start with an existing box or your own specification. Configure these six areas around your installation, procurement and brand requirements.
String inputs, outputs and inverter connections matched to your diagram, with independent MPPT circuits kept separate where required.
DC breakers or isolators, PV fuses and surge protection, with ratings and coordination reviewed for your circuit.
Steel or plastic housing, cable entries and internal layout planned around your installation and maintenance access.
Cable sizes, connectors, polarity markings and internal routing specified for the approved configuration.
Your logo, nameplate, circuit labels and packaging for a consistent brand presentation.
Drawings, component lists and inspection records, with market-specific document requirements reviewed for your project.
Send it with your quantity and destination to start a configuration review.
Inside the combiner box
Explore eight input and voltage configurations. Some cards currently share an illustrative reference image; actual components and wiring depend on the approved configuration drawing.
Project configuration examples
Two customer projects, one plastic and one steel, showing how the box configuration follows the string count, current and installation site.
Solar installer / South Africa / Rooftop PV
Two rooftop strings combined into one inverter input, supplied as a pre-wired box the installer reorders under one part number.
Why this enclosure: A compact, lightweight housing for wall mounting on residential roofs, with the same layout on every repeat order.
Engineering procurement / Multi-string PV
Six PV strings combined into one 125A output for a larger array, with internal space for organized wiring and maintenance.
Why this enclosure: A steel, lockable enclosure for sites where the box is exposed to impact or unauthorized access.
Project gallery
Austria · 1.1 MW
Hillside Farm Solar Project
Malaysia · 10 kW
Oilfield PV & Energy Storage
Xinjiang, China · 10 MW
Ground-Mount Solar Project
Zhejiang, China · 46 kW
Rooftop Solar Project
United States · 32 kW
PV Combiner Box Installation
Applications & partnerships
Work with Soltree as an EPC contractor, solar installer or OEM partner to align the box configuration with your installation and procurement requirements.
Plan configurations around roof zones, inverter connections and maintenance access, with clear circuit identification across the installation.
Discuss enclosure requirements, cable entries and supply batches around the site environment and project delivery schedule.
Agree a repeat-order configuration with consistent components, brand identification and packaging requirements for your market.
Meet your manufacturing partner
With over 15 years of manufacturing expertise, Soltree provides DC protection products and PV combiner boxes at competitive prices. We support installers, project buyers and OEM partners with plastic or steel enclosures, custom configurations and coordinated project supply.
Our range includes DC circuit breakers, surge protectors, PV fuses and complete combiner box assemblies. From component selection and enclosure layout to branding and packaging, we help turn your project requirements into an agreed production specification for consistent repeat orders.
Customer satisfaction
Dedicated support and responsive service.
Source DC protection components or a complete PV combiner box, configured for your project.
Overcurrent protection
DC breakers selected for your system voltage, current, breaking capacity and pole arrangement.
Explore DC MCBs →Surge protection
PV surge protection matched to your system voltage, earthing arrangement and box design.
Explore DC SPDs →String protection
PV fuses, holders, terminals and wiring specified for your string current and circuit layout.
Discuss Components →Configured assemblies
Plastic or steel boxes with configured inputs, outputs and protection, plus OEM branding options.
View Configurations →Inside Soltree
Production workshops, quality inspection, warehousing and our technical team — from manufacturing to packing and shipping.
From enquiry to supply
Agree the configuration, approval requirements and supply scope before production begins.
Share your drawing, inverter details, quantity and destination. Flag any requirements still to be decided.
Review the circuit, protection components, enclosure layout and required documents together.
Approve drawings and the component list before production. Confirm whether a sample or first article is needed.
Coordinate inspection, labeling, packing and shipment batches against the agreed delivery plan.
Selection · Customization · Project orders
Answers to common questions about inverter connections, outdoor enclosures, OEM options and project supply. Have a drawing or specification? Send it with your enquiry for review.
A PV combiner box brings string circuits into an organized enclosure for connection and protection. Depending on the design, it combines strings into a shared output or keeps circuits separate for independent inverter inputs. It does not convert DC power to AC.
The inverter connection plan determines whether an external box is needed. Review its available string inputs and built-in protection against the array layout and project requirements. Send the inverter data sheet and string plan rather than selecting a box by system power alone.
Start with the inverter model and wiring diagram. Confirm string inputs, outputs, design voltage and current, then review protection and enclosure requirements. Our configuration examples are references; the final selection follows your approved project specification.
The component list is configuration-specific. Our project examples include PV fuses, a DC breaker and surge protection. Switching devices, cable sizes and connections are reviewed together before approval.
Yes, with a layout that preserves the independent circuits required by the inverter. Multiple outputs do not necessarily share one combined bus. Send the inverter model and wiring diagram so we can review each circuit and combining point.
These labels describe input and output counts. A 2-in / 1-out design typically combines two strings, while a 2-in / 2-out design can preserve two separate circuits. Always check the wiring diagram: the label alone does not confirm internal connections or MPPT compatibility.
Provide module Voc and Isc, modules per string, parallel string count and the site minimum temperature. The design review must account for cold-weather string voltage, inverter limits, cable ratings and protection coordination. A power rating in kW alone is insufficient.
Only use a box approved for the intended circuit. Our featured examples are PV DC configurations. AC aggregation and battery protection require separate reviews of device ratings, fault current, switching and wiring; a matching voltage label alone does not establish suitability.
Our featured plastic and steel boxes specify IP65. Confirm the selected model, seals, cable entries and site conditions before installation; an IP65 rating does not permit submersion.
Our plastic project example prioritizes light weight and compact wall mounting. The steel example adds a lockable housing for exposed sites. Choose around installation space, access and environmental requirements.
Share the site temperature range, sun exposure, humidity and salt or chemical exposure. Enclosure material, seals, component operating limits and thermal performance must be reviewed for that location. The featured IP65 rating alone does not confirm UV, corrosion or temperature suitability.
Our two featured customer configurations are pre-wired assemblies. Confirm the supplied components, external terminations, cable entries and installation documents in your order specification. Pre-wiring still requires on-site mounting, connection and commissioning.
Use a qualified PV installer or electrician following the supplied instructions and local requirements. Commissioning includes checks of polarity, connections, protective earthing and the approved circuit arrangement. PV conductors can remain live in daylight after the inverter is switched off.
Follow the selected assembly instructions for inspection intervals. Check for water ingress, damaged seals, loose or overheated connections and protection-device status. Internal work requires qualified personnel, isolation of all relevant sources and verification of a safe working condition; never open fuse holders under load.
Use the approved component list and device instructions. Match the fuse type and electrical ratings, or the SPD module and compatible base. Send the box identification and component label for review before substituting a part.
Yes. Soltree reviews circuit inputs and outputs, protection components, enclosure layout, cable entries and wiring against your drawing. OEM options include your logo, nameplate, circuit labels and packaging. The quotation and approved specification define the final scope.
Yes, cable entry positions, cable sizes, connectors and internal routing can be specified during layout review. Include your cable and mating-connector details so mechanical fit, electrical compatibility, sealing and installation access can be checked together.
Include a separate schedule for functions such as string monitoring, remote alarms or reverse-current protection. Specify the measurements, interface and operating requirements. These are project requirements to review, rather than standard features of every configuration shown here.
Send the standards, certificates and inspection records required by your project or market. We will confirm which documents apply to the proposed assembly and components. Component certificates do not automatically certify the complete box.
The agreed scope should identify the wiring diagram, component list, enclosure layout, electrical ratings, labels, packaging and required documents. Confirm any sample approval criteria and inspection requirements before releasing the order for production.
Yes. Agree a repeat-order configuration with defined components, layout, identification and packaging. Reference the previous order and approved drawing revision, and confirm any proposed changes before production so different batches remain aligned with your project requirements.
MOQ and production lead time are quoted for the agreed configuration, quantity and sample requirements. Include your destination and target arrival date so production and transit can be planned separately.
Request a sample or first article with your enquiry. Its specification, cost and schedule will be confirmed before proceeding; agree any approval criteria before production.
Email your single-line diagram, inverter model, electrical requirements and bill of quantities to shawn@cnsoltree.com. Include enclosure requirements, mandatory documents, destination and delivery milestones. You can also start with the enquiry form below and send drawings by email.
Packing, shipment batches, destination and delivery responsibilities are agreed with the order. Include handling or labeling requirements in your enquiry.
Confirm the warranty period, coverage and support arrangements in your quotation or contract. For a product issue, send the order reference, configuration and photos to help us review it.
Ask for design, sample, tooling and production costs to be identified in the quotation. Charges depend on the requested scope; confirm ownership and reuse terms if your project requires dedicated tooling or a proprietary enclosure.
Custom box · OEM · Project quotation
Have a complete specification or just an initial layout? Send what you have and tell us which details need support.
For drawings and attachments, email us directly with your project name.
Share your requirements for a configuration and quotation discussion.
Product selection & quotations
Tell us your product requirements. Our team will help you find the right solution.
We use cookies to improve your experience. By continuing to visit this site you agree to our use of cookies. Privacy Policy