Soltree Logo
EN
Steel PV combiner box mounted on a solar carport column with cable tray

Application example · Solar carport

Lockable Steel Combiner Boxes for Solar Carports

Carport combiner boxes sit on columns within reach of cars, trolleys and passers-by. Here is how we configure a 6-string steel box that stands up to the site and is the same on every column.

Application
Solar carport / car park
Configuration
6 in / 1 out · 125A
Enclosure
Steel · IP65 · lock & key
Soltree scope
Pre-wired box, labels, packing

The challenge

A Combiner Box Within Reach of Cars and Shoppers

On a solar carport, the combiner boxes are mounted on the carport columns at about shoulder height, a few metres from moving cars and shoppers. The installer can’t fence them off, and the site owner expects them to look tidy for years.

A plastic box that works well on a residential roof is often the wrong choice here. The site sets four clear requirements:

Impact resistance

Boxes sit within reach of car doors, trolleys and bumpers.

No public access

Only maintenance staff should be able to open the door.

Per-string protection

Six parallel strings per box, each fused individually so one fault cannot feed the others.

The same box on every column

One part number and one layout, so any technician can service any box on site.

This page shows a typical configuration and how we approach it. It does not describe a specific customer project. Final components, ratings and documents follow your approved specification.

Our solution

Six Strings, One Protected Output, a Box People Can’t Easily Open

  1. 6 PV strings
  2. 15A fuse per string
  3. 125A DC breaker
  4. 40kA SPD
  5. Inverter input
  • Steel instead of plastic. A steel enclosure resists knocks in a car park, and the safety lock keeps the door closed to anyone without a key.

  • A fuse on every string. Six 15A PV fuses stop a faulty string from being back-fed by the other five.

  • A 125A DC breaker on the output. It leaves headroom over the combined string current and gives technicians a visible point to isolate the box.

  • Bottom cable entry. Glands on the bottom face let cables drop straight into the cable tray running down the column, and keep rain out of the entries.

Inside the box

What Goes Into the Combiner Box

PV string fuses

6 × 15A PV fuses

Protect each string individually against reverse current from the parallel strings.

DC circuit breaker

125A DC breaker

Overload and short-circuit protection on the combined output, and isolation for maintenance.

Surge protection

500V DC SPD · 40kA max

Limits lightning-induced transients before they reach the inverter.

Enclosure

Steel · IP65 · safety lock

Impact-resistant, weather-sealed and tamper-proof for public sites.

Cable entries

6 in + 1 out + earth

Arranged on the bottom face for a straight drop into the cable tray.

Wiring & labels

Pre-wired, polarity-marked

Circuit labels and polarity markings speed up installation and inspection.

Full specifications

Reference model
PCB-M6in-05
PV array inputs / outputs
6 / 1
DC circuit breaker
125A
PV fuse rating
15A × 6
Surge protection
500V DC, 40kA max discharge current
Enclosure
Steel, high impact resistance
Security
Safety lock & key
Protection level
IP65
Applicable systems
Grid-tied / off-grid PV

Customization

What Can Be Built to Your Project

  • Mounting brackets

    Column, wall or rail brackets sized to the posts or structure on your site.

  • Cable entry layout

    Gland sizes and positions matched to your cable sizes and tray routing.

  • Circuit count & ratings

    Inputs, outputs and fuse, breaker and SPD ratings matched to your string plan and inverter.

  • Labels & branding

    String labels numbered to your layout drawing, plus your logo and nameplate on the door.

How we deliver

From Your Drawing to a Packed Box

  1. 1

    Project brief

    You send the string plan, inverter details, quantity and destination, plus a photo of the mounting location if you have one.

  2. 2

    Configuration review

    We check fuse, breaker and SPD ratings against your module and inverter data, and propose the enclosure and cable entry layout.

  3. 3

    Specification approval

    You approve the drawing and component list before production. A sample or first article can be agreed at this stage.

  4. 4

    Production & delivery

    Boxes are assembled, inspected, labelled and packed, then shipped according to the agreed delivery plan.

PCB-M6in-05 combiner box interior with 125A DC breaker and 15A fuses
Interior layout
Open steel PV combiner boxes with installed protection components and wiring
Assembly in our workshop
Staff fitting protective foam corners to a steel enclosure before packing
Protective packaging

Soltree products

Products Used in This Configuration

Similar project · Quotation

Planning a Carport or Multi-String PV Project?

Send us:

  • Number of strings and the module Voc / Isc
  • Inverter model and number of MPPT inputs
  • Mounting location (column, wall or rail) and cable sizes
  • Quantity, destination and any branding requirements

Drawings by email: shawn@cnsoltree.com