Soltree Logo
EN
HT 8-way plastic PV combiner box wall-mounted beside a rooftop solar array

Application example · Residential rooftop PV

2-In / 1-Out Plastic Combiner Box for Residential Rooftops

How a compact plastic combiner box is configured when an installer combines two rooftop strings into one inverter input and wants the same pre-wired box on every job.

Application
Residential rooftop PV
Configuration
2 in / 1 out · 600V DC
Enclosure
Flame-retardant plastic · IP65
Soltree scope
Pre-wired box under one part number

The challenge

Many Small Roofs, Little Time on Each

Residential installers usually work on many small systems with similar layouts. Every hour spent wiring a combiner box on a roof or an exterior wall is an hour not spent on the next job.

A box that arrives pre-wired, mounts quickly and is reordered under one part number saves time on every roof. The installer’s requirements are:

Light and compact

The box is carried onto the roof or mounted on an exterior wall, so it needs to be small and light.

Quick installation

A pre-wired assembly with labelled terminals reduces wiring time and mistakes on site.

Surge protection

Rooftop arrays are exposed to lightning-induced surges, so an SPD on the DC side protects the inverter.

Repeat orders

The installer wants the same components and layout in every batch, ordered under one part number.

This page shows a typical configuration and how we approach it. It does not describe a specific customer project. Final components, ratings and documents follow your approved specification.

Our solution

Two Strings, One Inverter Input, the Same Box on Every Job

  1. 2 PV strings
  2. 15A fuse per pole
  3. 63A DC breaker
  4. 40kA SPD
  5. Inverter input
  • A light plastic housing. Flame-retardant hard plastic keeps the box light enough to carry onto a roof, and IP65 sealing suits outdoor walls.

  • Fuses on both poles. Four 15A PV fuses protect the positive and negative pole of each of the two strings.

  • A 63A DC breaker on the output. Provides overload and short-circuit protection and a clear isolation point for the inverter connection.

  • Pre-wired under one part number. Same components and layout in every batch, so installers reorder without re-checking the specification.

Inside the box

What Goes Into the Combiner Box

PV string fuses

4 × 15A PV fuses

Fuse both the positive and negative pole of each of the two strings.

DC circuit breaker

63A DC breaker

Provides overload and short-circuit protection on the combined output, and isolates it for maintenance.

Surge protection

500V DC SPD · 40kA max

Limits lightning-induced transients before they reach the inverter.

Enclosure

Flame-retardant plastic · IP65

Lightweight, weather-sealed housing with a clear cover for checking device status.

Connections

PV connectors in · glands out

Strings plug in with PV connectors; output and earth cables enter through sealed glands.

Wiring & labels

Pre-wired, polarity-marked

Circuit labels and polarity markings make installation and inspection quicker on site.

Full specifications

Reference model
HT-8Way-2in1out-600VDC
PV string inputs / outputs
2 / 1
Max system voltage
600V DC
DC circuit breaker
63A
PV fuse rating
15A × 4
Surge protection
500V DC, 40kA max discharge current
Enclosure
Flame-retardant hard plastic
Protection level
IP65
Applicable systems
On-grid / off-grid PV

Customization

What Can Be Built to Your Project

  • Circuit count

    Inputs and outputs matched to your string plan and inverter. Two inputs and one output is one option.

  • Ratings & components

    Breaker, fuse and SPD ratings are reviewed against your string Voc, Isc and system voltage.

  • Connector type

    PV connectors or cable glands, matched to the cables and mating connectors you use.

  • Enclosure size

    Module width and housing size chosen for the components, with space for wiring.

  • OEM identification

    Your logo, nameplate, circuit labels and packaging.

  • Repeat-order build

    A fixed component list and layout under one part number for consistent batches.

How we deliver

From Your Drawing to a Packed Box

  1. 1

    Project brief

    You send the string plan, inverter details, quantity and destination, plus a photo of the mounting location if you have one.

  2. 2

    Configuration review

    We check fuse, breaker and SPD ratings against your module and inverter data, and propose the enclosure and cable entry layout.

  3. 3

    Specification approval

    You approve the drawing and component list before production. A sample or first article can be agreed at this stage.

  4. 4

    Production & delivery

    Boxes are assembled, inspected, labelled and packed, then shipped according to the agreed delivery plan.

HT-8Way-2in1out-600VDC combiner box interior with 63A DC breaker and fuses
Interior layout
Worker wiring a combiner box beside cable processing equipment
Wiring in our workshop
Staff fitting protective foam corners to an enclosure before packing
Protective packaging

Soltree products

Products Used in This Configuration

Similar project · Quotation

Supplying Residential Rooftop Installations?

Send us:

  • Number of strings and the module Voc / Isc
  • Inverter model and number of MPPT inputs
  • Connector type and cable sizes
  • Monthly or batch quantity, destination and branding requirements

Drawings by email: shawn@cnsoltree.com

See more combiner box configurations

Chat with Soltree

Product selection & quotations

Tell us your product requirements. Our team will help you find the right solution.