Circuit Breaker
STZ-63 DC MCP 6kA 1P 2P 3P 4P 500V 1000V
STZ-63 is the standard-series option for DC distribution projects requiring 6kA breaking capacity. Choose from B, C and D trip curves and 1P, 2P, 3P or 4P configurations to match the circuit requirements. Confirm the applicable 500V or 1000V DC rating and wiring arrangement for the exact configuration before ordering.
Key Features
- 6kA breaking capacity for DC circuit protection.
- 1P, 2P, 3P and 4P configuration options.
- B, C and D trip-curve options to suit the load.
- 500V / 1000V DC options, subject to the selected pole configuration and approved wiring.
Samples available · OEM pricing on request · Ships worldwide
Application
STZ-63 provides overload and short-circuit protection for DC distribution circuits within the ratings of the selected configuration. Review the system voltage, load current, prospective fault current and required trip curve when selecting the breaker.
For solar PV or battery projects, supply the circuit diagram and system parameters so the exact model and wiring arrangement can be checked. Pole count alone does not establish the permissible DC voltage.
Specifications
Review the series options below. Confirm the rated current, DC voltage, pole arrangement and breaking capacity at that voltage for the exact configuration quoted.
| Parameter | Series option |
|---|---|
| Model | STZ-63 |
| Circuit Type | DC |
| Breaking Capacity | 6kA |
| Pole Options | 1P, 2P, 3P, 4P |
| Voltage Options | 500V DC / 1000V DC, subject to selected configuration |
| Trip Curve Options | B / C / D |
Selection & Wiring
Select the pole configuration and B/C/D trip curve to match the circuit design. The 500V and 1000V options are configuration-dependent; do not assume that every pole option supports both voltages.
Follow the documentation for the selected model for polarity, terminal connections and any permitted series connections. Confirm the required breaking capacity against the prospective fault current at the installation point.
Ordering Information
For a quotation, send the STZ-63 model name, required DC voltage, rated current, poles, B/C/D trip curve, quantity and destination market. Include the wiring diagram and any documentation requirements so the configuration can be confirmed.
More in Circuit Breaker
Circuit Breaker
MCB 1P AC 6 – 63A Circuit breaker
Single-pole miniature circuit breaker, 6 – 63A, B/C/D-curve, ideal for residential lighting and socket circuit protection.
Circuit Breaker
MCB 2P AC 6 – 63A Circuit breaker
Double-pole miniature circuit breaker, 6 – 63A, B/C/D-curve, simultaneously disconnects live and neutral for full circuit isolation.
Circuit Breaker
MCB 3P AC 6 – 63A Circuit breaker
Three-pole miniature circuit breaker, 6 – 63A, B/C/D-curve, designed for three-phase industrial equipment and motor protection.
Circuit Breaker
MCB 4P AC 6 – 63A Circuit breaker
Four-pole miniature circuit breaker, 6 – 63A, B/C/D-curve, full three-phase + neutral protection for TN-S and TN-C-S systems.